src/ethernet/phy/Dp83848Phy.lvt
namespace Livt.IO.Phy
using Livt.IO
/**
* DP83848 Clause-22 management for MII, advertising 10/100 full duplex only.
* Owns the borrowed MDIO controller exclusively. Board supplies the 25 MHz
* reference, hardware reset, and startupReady. Restart is a toggle. Errors
* revoke readiness and retry after POLL; half duplex is never admitted.
*/
component Dp83848Phy<PHY_ADDRESS: int = 1, POLL: Time = 10ms> : IEthernetLinkStatus
{
static assert PHY_ADDRESS >= 0 && PHY_ADDRESS <= 31, "Clause-22 address required"
static assert POLL >= 1us, "Positive polling interval required"
// Basic control register.
const BMCR: byte = 0
// Basic status register; read twice for latched-low link status.
const BMSR: byte = 1
// First PHY identification register.
const PHY_ID1: byte = 2
// Second PHY identification register.
const PHY_ID2: byte = 3
// Autonegotiation advertisement register.
const ANAR: byte = 4
// Resolved physical link status register.
const PHYSTS: byte = 16
// RMII/bypass configuration register.
const RBR: byte = 23
// DP83848 manufacturer identification.
const EXPECTED_ID1: logic[16] = 0x2000
// DP83848 model identification without revision bits.
const EXPECTED_ID2: logic[16] = 0x5C90
// Ignore PHY revision when comparing model identity.
const MODEL_MASK: logic[16] = 0xFFF0
// Basic-control software reset bit.
const SOFTWARE_RESET: logic[16] = 0x8000
// Clear RMII mode while preserving unrelated configuration.
const MII_MODE_MASK: logic[16] = 0xFFDF
// Advertise IEEE selector plus 10-full and 100-full.
const FULL_DUPLEX_ADVERTISEMENT: logic[16] = 0x0141
// Enable and restart autonegotiation.
const RESTART_AUTONEGOTIATION: logic[16] = 0x1200
// Basic status requires link up and autonegotiation complete.
const LINK_NEGOTIATED: logic[16] = 0x0024
// Check link, duplex, loopback, and negotiation status.
const PHYSICAL_STATUS_MASK: logic[16] = 0x001D
// Require link, full duplex, negotiation complete, and no loopback.
const PHYSICAL_READY: logic[16] = 0x0015
// Resolved speed bit: set for 10 Mb/s.
const SPEED_10: logic[16] = 2
// Bound software-reset register polling.
const RESET_POLL_LIMIT: uint = 10000
// Borrowed exclusive management bus and board startup/restart controls.
mdio: IMdioController
startupReady: bool
restart: bool
// Negotiation state and last observed restart request.
seenRestart: bool
linked: bool
rate: EthernetSpeed
// Construction-time polling interval in the inherited context.
POLL_TICKS: uint
// Published management diagnostics; stage 5 denotes a resolved link.
public failed: out bool
public stage: out byte
public identifier1: out logic[16]
public identifier2: out logic[16]
public bmsr: out logic[16]
public physicalStatus: out logic[16]
/**
* Binds the management bus and board startup/restart controls.
*/
new(mdio: IMdioController, startupReady: bool, restart: bool)
{
this.mdio = mdio
this.startupReady = startupReady
this.restart = restart
POLL_TICKS = this.context.TicksFor(POLL)
}
/**
* Exposes only a resolved, full-duplex link after board startup.
*/
process Status[]()
{
this.ready = linked && startupReady && restart == seenRestart
this.speed = EthernetSpeed.Unknown
if (this.ready) {
this.speed = rate
}
}
/**
* Identifies the PHY, selects MII, and monitors negotiated speed and duplex.
* Explicit states retain the sampling and MDIO transaction sequence.
*/
process Manage()
{
var value: logic[16] = 0
var status: logic[16] = 0
var physical: logic[16] = 0
var ticks: uint = 0
var attempts: uint = 0
var nextRate = EthernetSpeed.Unknown
state Initialize {
this.linked = false
this.failed = false
this.seenRestart = restart
this.stage = 1
if (!startupReady) {
goto Initialize
}
}
if (mdio.Read(PHY_ADDRESS as byte, PHY_ID1, value) != EthernetResult.Success) {
goto Failed
}
this.identifier1 = value
if (value != EXPECTED_ID1) {
goto Failed
}
if (mdio.Read(PHY_ADDRESS as byte, PHY_ID2, value) != EthernetResult.Success) {
goto Failed
}
this.identifier2 = value
if ((value & MODEL_MASK) != EXPECTED_ID2) {
goto Failed
}
this.stage = 2
if (mdio.Write(PHY_ADDRESS as byte, BMCR, SOFTWARE_RESET) != EthernetResult.Success) {
goto Failed
}
attempts = 0
state ResetWait {}
if (mdio.Read(PHY_ADDRESS as byte, BMCR, value) != EthernetResult.Success) {
goto Failed
}
if ((value & SOFTWARE_RESET) != 0) {
attempts++
if (attempts >= RESET_POLL_LIMIT) {
goto Failed
}
goto ResetWait
}
if (mdio.Read(PHY_ADDRESS as byte, RBR, value) != EthernetResult.Success) {
goto Failed
}
// Clear RMII_MODE; preserve all other fields.
if (mdio.Write(PHY_ADDRESS as byte, RBR, value & MII_MODE_MASK) != EthernetResult.Success) {
goto Failed
}
if (mdio.Write(PHY_ADDRESS as byte, ANAR, FULL_DUPLEX_ADVERTISEMENT) != EthernetResult.Success
|| mdio.Write(PHY_ADDRESS as byte, BMCR, RESTART_AUTONEGOTIATION) != EthernetResult.Success) {
goto Failed
}
this.stage = 4
state Poll {}
if (!startupReady || restart != seenRestart) {
goto Initialize
}
if (mdio.Read(PHY_ADDRESS as byte, BMSR, status) != EthernetResult.Success
|| mdio.Read(PHY_ADDRESS as byte, BMSR, status) != EthernetResult.Success
|| mdio.Read(PHY_ADDRESS as byte, PHYSTS, physical) != EthernetResult.Success) {
goto Failed
}
this.bmsr = status
this.physicalStatus = physical
nextRate = EthernetSpeed.Mbps100
if ((physical & SPEED_10) != 0) {
nextRate = EthernetSpeed.Mbps10
}
// A speed transition revokes readiness for at least one edge.
if (rate != nextRate) {
this.linked = false
}
state {}
this.rate = nextRate
this.linked = (status & LINK_NEGOTIATED) == LINK_NEGOTIATED && (physical & PHYSICAL_STATUS_MASK) == PHYSICAL_READY
this.stage = 4
if (linked) {
this.stage = 5
}
ticks = 0
state Wait {}
if (!startupReady || restart != seenRestart) {
goto Initialize
}
ticks++
if (ticks < POLL_TICKS) {
goto Wait
}
goto Poll
state Failed {
this.failed = true
this.linked = false
this.stage = 6
ticks = 0
}
state Retry {}
ticks++
if (ticks < POLL_TICKS && restart == seenRestart) {
goto Retry
}
goto Initialize
}
}